Quality Tests

Regency Glass is BS EN1279 accredited. Having fully implemented part 6 of the standard (Factory Production Control), we undertake daily testing to ensure that our products meet the highest standards. These include component and finished goods checks. Component testing includes:

  • Glass – correct product ordered/delivered and condition
  • Spacer bar – correct product ordered/delivered and within dimension tolerances
  • Desiccant – condition in accordance with manufacturers activity requirements for use
  • Sealant – correct product ordered/delivered and within usage date
  • Component fixings – correct product ordered/delivered and within dimensional tolerances
  • All batch numbers are recorded for future reference

Machinery testing includes:

  • Sealant mix and dispensing equipment - ratios checked daily ensuring correct chemical composition of sealant
  • Glass wash machines – demineralising crystals and water treatment supply checked to ensure water clarity thereby reducing any glass contamination
  • Spacer cutting saws – dimensional tolerance calibrated
  • Toughening plant – break test on glass to ensure that the minimum number of pieces required per square inch is attained and maintained
  • PIB sealing machines – weight test of applied sealant to ensure correct amount of sealant is being applied
  • All machinery is serviced in accordance with our maintenance program by our two on-site engineers

Final product testing includes:

  • Glass is inspected for marks and scratches as it travels along our production line
  • Random finished units are checked prior to loading in accordance with our factory production control (FPC) procedure. This includes:
    • Sealant depth
    • PIB spread
    • Marks
    • Labeling
    • Gas concentrations where applicable
 
Corporate Logo Design